| Test Parameters | Specification |
|---|---|
| Operating ambient temp. Range | -10~+65°C |
| Insulation Resistance | 100MΩ above(at 500VDC) |
| Withstand Voltage /HV | Current-carrying and non-current-carrying metal parts, Between terminal and earthing: 1500VAC, 50/60HZ |
| Contact Resistance | Should be less than 50 mOhm at 6 Amp Initially. |
| Life | Mechanical : 100000 cycles |
| Electrical: 100000 cycles at rated 240VAC 6A Resistive Load. | |
| Humidity | 85%RH(+5~+35°C) |
| IP Rating | 1.Open-type switch housing provides IP20 protection. |
| Vibration testing/ Mechanical Shock |
Vibration under testing- IEC 60068-2-6 Mechanical shock under testing- IEC 60068-2-6 |
| RoHS |
comply |
| Rated Current | 6 Amp ; 1.5 Amp |
| Operating Temperature | -25°C to 60°C |
| Storage Temperature | -30°C to 70°C |
| Terminal Torque | 0.8 N-m minimum |
| AC:15 | Ue: 250V Ie: 6A Ith: 10A ( IEC 60947-5-1) |
| DC:13 | Ue:24V Ie:1.5A ( IEC 60947-5-1) |
| MV Drop | should be less than 50mV at 6 Amp Initially. |
| Lug Feasibility | Barrel type,'U' type,Bare Cable 0.5mm2 to 2.0 sq. mm Cable. |
| Actuating Rod & Head | Round Head |
| CE as per IEC 60947-5-1 | Under testing with Positive Opening |